Custom Wall-Mounted Outdoor Electrical Enclosure

Custom wall-mounted outdoor electrical enclosure featuring a sloped rain hood, front access door with recessed latch, side mounting tabs and a lower bolted panel section. Manufactured to customer drawings for outdoor electrical and control equipment, with customizable dimensions, mounting interfaces, cable-entry provisions and sealing details.

  • Material :

    Stainless Steel / Carbon Steel / Zinc-Coated Steel / Aluminum
  • Common Grade :

    Stainless Steel 304 / 316; SPCC / DC01; SGCC; Aluminum 5052
  • Thickness :

    Customized to approved drawings
  • Size :

    Customized to approved drawings
  • Roof Design :

    Sloped Overhanging Rain Hood
  • Surface Finish :

    Powder Coating / Brushing / Passivation / Anodizing, as Applicable
  • Door & Lock :

    Front Access Door with Recessed Latch
  • Manufacturing Process :

    Laser Cutting, Punching, Bending, Joining and Finishing
  • Sealing Options :

    Project-Specified Door Gaskets and Sealing Interfaces
  • Ingress Protection :

    Target Rating and Verification Requirements to Be Agreed
  • Cable Entry :

    Custom Cut-Outs / Gland Plates as Specified
  • Installation Type :

    Wall-Mounted / Bracket-Mounted
  • Supply Scope :

    Enclosure with Optional Mechanical Hardware Installation
  • Application :

    Outdoor Electrical Control Systems·Industrial Automation Equipment·Telecommunication Equipment·Power Distribution Accessories·Outdoor Monitoring Systems·Building & Infrastructure Equipment
  • Overview

    wall_mounted_enclosure_application

    Wall-mounted outdoor electrical enclosures must balance equipment access, installation requirements and environmental protection.

    This custom metal enclosure features a sloped overhanging roof, a front access door with recessed latch hardware, side mounting tabs and a lower bolted panel section. These structural features provide a practical starting point for customer-specific outdoor electrical enclosure designs.

    Dimensions, mounting arrangements, cable-entry positions and sealing interfaces can be adapted according to approved drawings. Any required IP or NEMA protection rating must be evaluated for the complete enclosure configuration, including doors, joints, cable fittings and installed accessories.

    Applications: Outdoor Electrical Control Systems·Industrial Automation Equipment·Telecommunication Equipment·Power Distribution Accessories·Outdoor Monitoring Systems·Building & Infrastructure Equipment

    Recommended Materials

    • Stainless Steel

      Stainless Steel

      304 stainless steel is a versatile option for outdoor enclosures requiring corrosion resistance and fabrication performance. Grade 316 may be considered for more demanding corrosive environments, depending on exposure conditions and project requirements.
    • Carbon & Zinc-Coated Steel

      Carbon & Zinc-Coated Steel

      SPCC or DC01 steel can be used for fabricated enclosure panels with a suitable protective coating system. SGCC zinc-coated sheet provides another material option, with attention to cut edges, joined areas and the final surface treatment.
    • Aluminum Alloy

      Aluminum Alloy 

      5052 aluminum is a lightweight, corrosion-resistant option for formed sheet metal enclosures. Its thickness, joining methods and surface finishing should be selected according to the required structure and operating environment.

     

    Read more materials

     

    Customization Options

    Enclosure Customization Options

    • Wall Mounting

      Wall Mounting

      Customize mounting-tab positions, fixing-hole patterns, bracket dimensions and installation clearances according to the wall structure and equipment layout.
    • Door & Cable Access

      Door & Cable Access

      Specify door hardware, locking options, gasket interfaces, cable-entry positions and removable gland plates to match the equipment arrangement.
    • Material & Finish

      Material & Finish

      Choose material grades, sheet thicknesses, surface finishes and enclosure dimensions according to the intended application and environmental conditions.

    Key Design Considerations

    • Ingress Protection Design

      Ingress Protection Design

      Roof overhang, door joints, panel connections and sealing details must be reviewed together for the required environmental protection.
    • Cable Entry Sealing

      Cable Entry Sealing

      Cable glands, cut-outs and blanking components must be selected and installed according to the complete enclosure protection requirements.
    • Mounting Strength

      Mounting Strength

      Mounting tabs, fasteners and wall conditions should be checked against the equipment weight and installation requirements.
    • Condensation & Ventilation

      Condensation & Ventilation

      Condensation control, ventilation and drainage requirements should be evaluated according to the equipment and operating environment without compromising the intended protection level.

    Manufacturing Process

    Manufacturing begins with drawing review, material cutting, punching and bending. Formed panels are joined, deburred and finished, followed by installation of specified locks, gaskets and mounting hardware. Final checks cover dimensional accuracy, door fit, hardware installation and agreed inspection requirements before packing.

     

    OEM Manufacturing Support 

    YT Manufacturing provides custom sheet metal enclosure fabrication based on customer drawings and project requirements. We support enclosure manufacturing, surface finishing and installation of specified mechanical accessories. Electrical system design and any required ingress-protection testing or verification must be defined separately within the project scope. Learn more on our Capabilities page

     

    Prototype production and DFM review are available for new projects before volume manufacturing. Learn more on our Capabilities page

    After-Sales Support

    We support quality feedback, replacement parts, repeat production and approved design updates for ongoing OEM projects according to the agreed project scope.

    FAQ

     
    Can you customize wall-mounting tabs and hole patterns?

    Yes. Mounting tabs, fixing-hole positions and bracket configurations can be customized according to approved installation drawings.

    Does this enclosure have an IP65 or IP66 rating?

    No specific IP rating is claimed for the pictured enclosure. Target protection requirements, design details and verification arrangements must be agreed upon for each project.

    Can the rain hood and door design be customized?

    Yes. Roof dimensions, door configurations, locking hardware and sealing interfaces can be reviewed according to the equipment and environmental requirements.

    Can you provide cable-entry cut-outs and sealing accessories?

    Yes. Custom cut-outs, gland plates, gaskets and specified mechanical hardware can be included according to the approved drawings and bill of materials.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.